Welcome To TUNKIA !    |   Electrical Measurement   |   Magnetic Measurement
You are here: Home » Products » Electrical Measurement » Advanced Multifunction Calibrator » TD1880 High-Precision Multi-Product Calibrator
Share to:

TD1880 High-Precision Multi-Product Calibrator

Availability:
Quantity:

Introduction

  • TD1880, a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC/DC voltage, current, phase adjustment and power, and also has the functions of pulse output and simulating DC resistance, thermocouple (TC), thermal resistance (RTD) and capacitance. Applied to calibrate 6½ and below digits multimeters or other electrical measuring instruments.


Reference

  • JJG 124-2005 Verification Regulation of Amperemeters, Voltmeters, Wattmeters and Ohmmeters.

  • JJF 1587-2016 Calibration Specification for Multimeters

  • JJF 1284-2011 Calibration Specification of Calibrators for Electrical Meters

  • JJF 1638-2017 Calibration specification of multifunctional standard source


Features

  • Electrical Parameters Output: Voltage is up to 1100 V, current is up to 30 A at a frequency 10 Hz ~ 500 kHz.

  • Resistance Simulation: Continuously variable range, 1 Ω ~ 1100 MΩ, pulse output range: 1 Hz ~ 2 MHz.

  • The output current has high stability (the typical value is better than 10 ppm/h) and high accuracy (the typical value is 50 ppm/a), and its measurement accuracy is higher than the international similar products.

  • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

  • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

  • TC and RTD simulation: Support for simulation of up to 8 types of TC and 6 types of RTD.  

  • Strong load capacity of AC, can drive various types of analogue meters and digital meters, so the applicable range of measured instruments is very wide.

  • The protection of voltage and current sources ensures high reliability under complex conditions.

  • Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

  • Transmitter Measurement (Option): Measure the secondary DC signal of the transmitters.

  • Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.

Specification


AC Voltage Output

Range

Resolution

Frequency   (Hz)

Accuracy   (k = 2, ppm*RD +μV)

Max.   Load

Current   (mA)

90   Days

(23   ±5) °C

1   Year

(23   ±5) °C

30   mV

100   nV

10   ≤ F≤ 45

600   + 6

800   + 6

50

45   < F < 400

80   + 5

100   + 5

400   < F < 10 k

80   + 10

100   + 10

10   k < F < 20 k

160   + 10

200   + 10

20   k < F < 50 k

800   + 10

1000   + 10

50   k < F < 100 k

2800   + 12

3500   + 12

100   k < F < 500 k

6000   + 50

8000   + 50

100   mV

1   μV

10   ≤ F≤ 45

250   + 8

300   + 8

50

45   < F < 400

80   + 5

100   + 5

400   < F < 10 k

80   + 10

100   + 10

10   k < F < 20 k

80   + 10

200   + 10

20   k < F < 50 k

280   + 10

350   + 10

50   k < F < 100 k

640   + 10

800   + 10

100   k < F < 500 k

1600   + 70

2000   + 70

300   mV

1   μV

10   ≤ F≤ 45

250   + 8

300   + 8

100

45   < F < 10 k

80   + 10

100   + 10

10   k < F < 20 k

80   + 10

200   + 10

20   k < F < 50 k

280   + 10

350   + 10

50   k < F < 100 k

640   + 10

800   + 10

100   k < F < 500 k

1600   + 70

2000   + 70


1   V

10   μV

10   ≤ F≤ 45

250   + 50

300   + 50

100

45   < F < 400

40   + 20

50   + 20

400   < F < 10 k

80   + 20

100   + 20

10   k < F < 20 k

160   + 20

200   + 20

20   k < F < 50 k

280   + 20

350   + 20

50   k < F < 100 k

640   + 20

800   + 20

100   k < F < 500 k

2000   + 600

2400   + 600

3   V

10   μV

10   ≤ F≤ 45

250   + 50

300   + 50

100

45   < F < 400

40   + 50

50   + 50

400   < F < 2 k

64   + 50

80   + 50

2   k < F < 10 k

80   + 50

100   + 50

10   k < F < 20 k

160   + 50

200   + 50

20   k < F < 50 k

280   + 50

350   + 50

50   k < F < 100 k

640   + 50

800   + 50

100   k < F < 500 k

2000   + 600

2400   + 600

10   V

100   μV

10   ≤ F≤ 15

250   + 30000

300   + 30000

100

15   < F < 45

250   + 650

300   + 650

45   < F < 400

40   + 150

50   + 150

400   < F < 2 k

64   + 150

80   + 150

2   k < F < 10 k

80   + 150

100   + 150

10   k < F < 20 k

160   + 150

200   + 150

20   k < F < 50 k

280   + 150

350   + 150

30   V

100   μV

10   ≤ F≤ 15

250   + 80000

300   + 30000

250

15   < F < 45

250   + 650

300   + 650

45   < F < 400

40   + 500

50   + 500

400   < F < 2 k

64   + 500

80   + 500

2   k < F < 10 k

80   + 500

100   + 500

10   k < F < 20 k

160   + 500

200   + 500

20   k < F < 50 k

280   + 500

350   + 500

100   V

1   mV

15   < F < 45

250   + 2000

300   +2000

250

45   < F < 400

40   + 1000

50   +1000

400   < F < 2 k

64   + 1000

80   + 1000

2   k < F < 10 k

80   + 1000

100   + 1000

10   k < F < 20 k

160   + 1000

200   + 1000

20   k < F < 50 k

280   + 1000

350   + 1000

300   V

1   mV

15   < F < 45

250   + 6000

300   + 6000

100

45   < F < 400

50   + 5000

50   + 5000

400   < F < 2 k

80   + 5000

80   + 5000

2   k < F < 10 k

80   + 5000

100   + 5000

10   k < F < 20 k

160   + 5000

200   + 5000

20   k < F < 50 k

280   + 5000

350   + 5000

1000   V

10   mV


45   ≤ F≤ 400

80   + 10000

100   + 10000

30

400   < F < 2 k

96   + 10000

120   + 10000

2   k < F < 10 k

120   + 10000

150   + 10000

  • Output Range: 3 mV ~ 1100 V; Display: 7 digits;

  • Distortion: <0.5 %;<1 % @ 10 mV…1 V ranges

  • Protection: Short-circuit protection, overload protection.


AC Current Output

Range

Resolution

Frequency   (Hz)

Accuracy   (k = 2, ppm*RD +μV)

Max.   Load

Current   (mA)

90   Days

(23   ±5) °C

1   Year

(23   ±5) °C

300   μA

1   nA

10   ≤ F≤ 20

400   + 0.2

500   + 0.2

30

20   < F < 45

300   + 0.1

350   + 0.1

45   < F < 400

240   + 0.1

300   + 0.1

400   < F < 2 k

320   + 0.2

400   + 0.2

2   k < F < 10 k

400   + 0.5

500   + 0.5

10   k < F < 20 k

4000   + 0.6

5000   + 0.6

20   k < F < 50 k

6400   + 0.7

8000   + 0.7

1   mA

10   nA

10   ≤ F≤ 20

400   + 0.5

500   + 0.5

30

20   < F < 45

200   + 0.1

250   + 0.1

45   < F < 400

160   + 0.1

200   + 0.1

400   < F < 2 k

160   + 0.2

200   + 0.2

2   k < F < 10 k

240   + 0.5

300   + 0.5

10   k < F < 20 k

2400   + 0.6

3000   + 0.6

20   k < F < 50 k

5600   + 0.7

7000   + 0.7

3   mA

10   nA

10   ≤ F≤ 20

400   + 1.5

500   + 1.5

30

20   < F < 45

200   + 0.1

250   + 0.1

45   < F < 400

160   + 0.1

200   + 0.1

400   < F < 2 k

160   + 0.2

200   + 0.2

2   k < F < 10 k

240   + 0.5

300   + 0.5

10   k < F < 20 k

1600   + 0.6

2000   + 0.6

20   k < F < 50 k

4800   + 0.7

6000   + 0.7

10 mA

100   nA

10   ≤ F≤ 20

400   + 5

500   + 5

30

20   < F < 45

200   + 0.5

250   + 0.5

45   < F < 400

80   + 0.5

100   + 0.5

400   < F < 2 k

160   + 1

200   + 1

2   k < F < 10 k

400   + 2

500   + 2

10   k < F < 20 k

1600   + 3

2000   + 3

20   k < F < 50 k

4800   + 4

6000   + 4

30   mA

100   nA

10   ≤ F≤ 20

400   + 15

500   + 15

30

20   < F < 45

200   + 2

250   + 2

45   < F < 400

80   + 2

100   + 2

400   < F < 2 k

160   + 3

200   + 3

2   k < F < 10 k

400   + 5

500   + 5

10   k < F < 20 k

1600   + 6

2000   + 6

20   k < F < 50 k

4800   + 7

6000   + 7

100   mA

1   μA

10   ≤ F≤ 20

400   + 50

500   + 50

30

20   < F < 45

200   + 5

250   + 5

45   < F < 400

40   + 5

50   + 5

400   < F < 2 k

80   + 10

100   + 10

2   k < F < 10 k

160   + 20

200   + 20

10   k < F < 20 k

800   + 30

1000   + 30

20   k < F < 30 k

2400   + 40

3000   + 40

30   k < F < 50 k

5000   + 40

6000   + 40

1   A

10   μA

10   ≤ F≤ 20

400   + 500

500   + 500

15

20   < F < 45

200   + 20

250   + 20

45   < F < 400

40   + 50

50   + 50

400   < F < 2 k

50   + 100

50   + 100

2   k < F < 10 k

160   + 500

200   + 500

10   k < F < 20 k

800   + 600

1000   + 600

20   k < F < 30 k

2400   + 700

3000   + 700

3   A

10   μA

10   ≤ F≤ 20

400   + 1500

500   + 1500

10

20   < F < 45

200   + 100

250   + 100

45   < F < 400

40   + 100

50   + 100

400   < F < 2 k

80   + 100

100   + 100

2   k < F < 10 k

160   + 500

200   + 500

10   A

100   μA

45   < F < 400

40   + 200

50   + 200

2.5

400   < F < 2 k

80   + 200

100   + 200

2   k < F < 10 k

160   + 500

200   + 500

30   A

100   μA

45   ≤ F≤ 400

80   + 600

100   + 600

2

400   < F < 2 k

80   + 600

100   + 600

2   k < F < 5 k

160   + 1500

200   + 1500

  • Output Range: 30 μA ~ 30 A; Display: 7 digits;

  • Distortion: <0.5 %;<1 % @ 300 μA…10 mA ranges

  • Protection: Short-circuit protection, overload protection.


DC Voltage Output

Range

Accuracy   (K = 2) (ppm*RD + μV)

Max.   Load Current

(mA)

Ripple Coefficient

(%)

24 Hours

90 Days

1   Year

30   mV

15 + 2

24 + 2

30   + 2

50

<   0.5

100   mV

12   + 2

20   + 2

25   + 2

50

<   0.5

300   mV

10   + 2

16   + 2

20   + 2

100

<   0.5

1   V

10   + 2

16   + 2

20   + 2

100

<   0.5

3   V

8   + 5

12   + 5

15   + 5

100

<   0.5

10   V

8   + 10

12   + 10

15   + 10

100

<   0.5

30   V

8   + 20

12   + 20

15   + 20

250

<   0.5

100   V

10   + 100

16   + 100

20   + 100

250

<   0.5

300   V

10   + 300

16   + 300

20   + 300

100

<   0.5

1000   V

10   + 1500

16   + 1500

20   + 1500

30

<   0.5

  • Output Range: ±(3 mV ~ 1100 V); Resolution: 0.0005 %*RG; Display: 7 digits

  • Range Switching: Automatic or Manual.


DC Current Output

Range

Accuracy   (K = 2)

(ppm*RD +   ppm*RG)

Max.   Load   Voltage

(V)

Ripple Coefficient

(%)

24 Hours


90 Days


1 Year

30 μA

50 +   0.01

80 +   0.01

100 + 0.01

11

<   0.5

100 μA

50 +   0.02

80 +   0.02

100 +   0.02

11

<   0.5

300 μA

50 +   0.02

80 +   0.02

100 +   0.02

11

<   0.5

1 mA

25 +   0.05

40 +   0.05

50 +   0.05

11

<   0.5

3 mA

25 +   0.05

40 +   0.05

50 +   0.05

11

<   0.5

10 mA

25 +   0.2

40 +   0.2

50 +   0.2

11

<   0.5

30 mA

25 + 0.5

40 +   0.5

50 +   0.5

11

<   0.5

100 mA

25 + 1

40 + 1

50 + 1

11

<   0.5

1 A

25 + 20

40 + 20

50 + 20

4

<   0.5

3 A

25 + 50

40 + 50

50 + 50

4

<   0.5

10 A

25 +   200

40 +   200

50 +   200

4

<   0.5

30 A

30 +   600

48 +   600

60 +   600

3.5

<   0.5

  • Output Range: ±(3 μA ~ 30 A); Resolution: 0.0005 %*RG; Display: 7 digits

  • Range Switching: Automatic or Manual.


AC/DC Power Output

DC Power

Range

Combination   of DC voltage range and DC current range.

Accuracy

DC voltage   accuracy + DC current accuracy.

AC Power

(45 Hz ~   65 Hz)


Range

Combination   of 30 V...300 V range and 10 mA…30 A range.

Accuracy

Range of 10   mA…30 mA: 0.05 %*FS

Range of 100   mA…30 A: 0.02 %*FS

Power   Factor

-1.0000…0.0000…+1.0000

  • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)


Capacitance

Range

Accuracy (k = 2) (%*RD+ nF   or μF)

Resolution

Allowable   Frequency

1.1 nF ~   3.2999 nF

0.5 +   0.04 nF

0.1 pF

10 Hz ~ 3   kHz

3.3 nF ~   10.9999 nF

0.25 +   0.04 nF

0.1 pF

10 Hz ~ 1   kHz

11 nF ~   32.9999 nF

0.25 +   0.4 nF

0.1 pF

10 Hz ~ 1   kHz

33 nF ~   109.999 nF

0.25 +   0.4 nF

1 pF

10 Hz ~ 1   kHz

110 nF ~   329.999 nF

0.25 +   0.3 nF

1 pF

10 Hz ~ 1   kHz

330 nF ~   1.09999 μF

0.25 + 1   nF

10 pF

10 ~ 600   Hz

1.1 μF ~   3.29999 μF

0.25 + 3   nF

10 pF

10 ~ 300   Hz

3.3 μF ~   10.9999 μF

0.25 + 10   nF

100 pF

10 ~ 150   Hz

11 μF ~   32.9999 μF

0.40 + 30   nF

100 pF

10 ~ 120   Hz

33 μF ~   109.999 μF

0.45 +   100 nF

1 nF

10 ~ 80   Hz

110 μF ~   329.999 μF

0.45 +   300 nF

1 nF

0 ~ 50 Hz

330 μF ~   1.09999 mF

0.45 + 1   μF

10 nF

0 ~ 20 Hz

1.1 mF ~   3.29999 mF

0.45 + 3   μF

10 nF

0 ~ 6 Hz

3.3 mF ~   10.9999 mF

0.45 + 10   μF

100 nF

0 ~ 2 Hz

11 mF ~   30 mF

0.75 + 30   μF

100 nF

0 ~ 0.6   Hz


Resistance

Range

Allowable   Current

Accuracy (k = 2), ppm*RD   +Ω

24 Hours

90 Days


1 Year

10 Ω

1 mA ~   150 mA

20 + 0.01

32 + 0.01

40 + 0.01

20 Ω

1 mA ~ 150   mA

15 +   0.015

24 +   0.015

30 +   0.015

100 Ω

1 mA ~ 80   mA

12 +   0.015

20 +   0.015

25 +   0.015

300 Ω

1 mA ~ 40   mA

12 + 0.02

20 + 0.02

25 + 0.02

1 kΩ

1 mA ~ 20   mA

12 + 0.02

20 + 0.02

25 + 0.02

3 kΩ

0.1 mA ~   6 mA

12 + 0.2

20 + 0.2

25 + 0.2

10 kΩ

0.1 mA ~ 2   mA

12 + 0.2

20 + 0.2

25 + 0.2

30 kΩ

10 μA ~   600 μA

15 + 1

24 + 1

30 + 1

100 kΩ

10 μA   ~200 μA

15 + 1

24 + 1

30 + 1

300 kΩ

1 μA ~ 60   μA

17 + 10

28 + 10

35 + 10

1 MΩ

1 μA ~ 20   μA

17 + 10

28 + 10

35 + 10

3 MΩ

250 nA ~   6 μA

30 + 150

48 + 150

60 + 150

10 MΩ

250 nA ~   2 μA

65 + 250

104 + 250

130 + 250

30 MΩ

25 nA ~   600 nA

125 + 2.5   k

200 + 2.5   k

250 + 2.5   k

100 MΩ

25 nA ~   200 nA

250 + 3 k

400 + 3 k

500 + 3 k

300 MΩ

2.5 nA ~   60 nA

1,5 k +   0.1 M

2.4 k +   0.1 M

3 k + 0.1   M

1000 MΩ

1 nA ~ 20   nA

7.5 k + 0.5   M

12 k +   0.5 M

15 k +   0.5 M

  • Output Range of Resistance: 0 Ω ~ 1100 MΩ; Resolution: 0.0004 %*RG; Display: 7 digits


Thermal Resistance (RTD)

Type

Temperature   Range (°C)

Accuracy (k = 2) (°C)

90 Days

1 Year

Pt385,   100 Ω

-200 ~ 0

0.05

0.05

0 ~ 300

0.08

0.08

300 ~ 850

0.12

0.12

Pt385,200   Ω

-200 ~   250

0.04

0.04

250 ~ 630

0.10

0.15

Pt385,500   Ω

-200 ~   -30

0.36

0.40

-30 ~ 630

0.10

0.11

Pt385,1000   Ω

-200 ~ 0

0.027

0.03

0 ~ 300

0.054

0.060

300 ~ 600

0.063

0.070

CU50

-50 ~ 150

0.09

0.09

CU100

-50 ~ 150

0.045

0.045


Thermocouple (TC)

Type

Temperature   Range (°C)

Accuracy (k = 2) (°C)

90 Days

1 Year

B

410 ~ 600

0.30

0.35

600 ~ 900

0.30

0.31

900 ~   1800

0.26

0.30

E

-200 ~ 0

0.10

0.11

0 ~ 600

0.07

0.08

600 ~   1000

0.09

0.10

J

-200 ~   -100

0.12

0.13

-100 ~   750

0.09

0.09

750 ~   1200

0.10

0.10

K

-200 ~   -100

0.15

0.20

-100 ~   1000

0.10

0.10

1000 ~   1370

0.12

0.12

N

-200 ~   -100

0.20

0.25

-100 ~   400

0.12

0.12

400 ~   1300

0.10

0.12

R

-50 ~ 50

0.30

0.40

50 ~ 300

0.28

0.32

300 ~   1000

0.22

0.23

1000 ~   1750

0.25

0.25

S

-50 ~ 50

0.30

0.40

50 ~ 300

0.31

0.34

300 ~   1000

0.24

0.24

1000 ~   1750

0.22

0.23

T

-200 ~   -100

0.17

0.25

-100 ~ 0

0.08

0.11

0 ~ 400

0.08

0.08


Pulse

  • Frequency Range: 1 Hz ~ 2 MHz, TTL Level

  • Resolution: 0.001 %*RG

  • Accuracy: ±(0.002 %*RD + 20 μHz)

  • Jitter: <20 ns


DC Small Signal Measurement (Option)

  • Range: 1 V, 10 V, 2 mA, 20 mA

  • Measuring Range: ± (0 ~12 V);± (0 ~ 24 mA)

  • Accuracy: ±(0.006 %*RD + 0.004 %*RG)

  • Notes: Applied to measure the secondary DC signal of the transmitters.


Previous: 