Home

Products

Advanced Multiproduct/Multifunction Calibrator

EV Charger/EV Charging Station Tester and Loads

Advanced Electrical Reference Standards

Electrical Resistance

AC DC Current Source and Meter

DC Power/Energy Standards

Wideband Power Source/Meter

Single-phase/Three-phase Electrical Meter

Single-phase/Three-phase Energy Meter standard Calibration Device

Safety Instrument Detection

High Voltage Standard Instrument

Industrial Instrument Testing

Calibrator for ESU Analyzer and Defibrillator Analyzer

Magnetic Parameters Measurement and Calibration

Electrical Steel Testing Equipment

Magnetic Material Testing Equipment

Videos

News

Solution

Download

About Us

Contact Us

English
Pусский
Español
Português
日本語
한국어
简体中文

You are here: Home » Solution » Solutions » How to Calibrate Clamp Meter-Equivalent Ampere-Turn Method

How to Calibrate Clamp Meter-Equivalent Ampere-Turn Method

Publish Time: 2024-03-07     Origin: Site

1. What is Clamp Meter


A clamp meter is an electrical testing tool that integrates a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.

Clamp meters are mainly used to test electrical parameters such as voltage, current, and power. In addition, clamp meters can be used to test the following electrical parameters: AC and DC current, voltage, power, AC frequency, DC resistance, temperature and capacitance


2. How to Calibrate Clamp Meter


The difficulty in improving the calibration accuracy of the clamp meter lies not in the accuracy of the current source, but in the uniformity and accuracy of the magnetic field generated by the wire under test.

Experiments on clamp meter ring diameters ranging from 10mm to 100mm have shown that when the length of the current-cutting wire reaches 1 meter, the system error of the straight wire portion of the clamp meter ring of all diameter specifications can be reduced to within -0.5%.

TUNKIA uses the standard source method to test clamp meters. The standard source method is often divided into single-turn method and equivalent ampere-turn method.


Calibration Method

Single-Turn Method

Equivalent Ampere-Turn Method

Applicable Accuracy

High and low accuracy

Low Accuracy

Cost

high

Low

Traceability

Easy

Difficult

DCI

Support

Support

ACI

Suitable for medium and high frequencies

Suitable for low frequencies, and the error is larger for medium and high frequencies.


3. Equivalent Ampere-Turn Method


Using the TUNKIA’s TD18 series Multi-function Calibrator with the TD1020 Current Coil, the user can choose the TD1020 Current Coil (50 turns) and pass in the AC and DC standard current of 20 A to achieve an equivalent current output of up to 1000 At, which is suitable for calibrating lower accuracy clamp meter or current clips of accuracy 1% and below.


Equivalent current output: 1000 A

Maximum current input: 22 Arms

Coil ampere-turns: 50 turns

DC measurement uncertainty: 0.3%

AC measurement uncertainty: 0.3%@50Hz, 0.5%@400Hz

Working frequency: DC, 45~400 H


 


For calibrating higher-precision clamp meters, you can choose TUNKIA's TD1000 and TD1050 Clamp Meter Calibration Device.


4. Operation Demo of Using TD1870+TD1020 to Test Clamp Meter