TE1000-AC-EU is a standard instrument designed for real-time electrical energy measurement during EV charger operation, with power and energy accuracy of Class 0.05 / 0.1.
This device, used with an EV as the load, performs metrological verification and energy checks on European-standard AC charging stations with Type 2 interfaces (per IEC 62196-2). Compared with conventional solutions, it offers superior portability, ease of use, and higher testing efficiency.
Benefits |
|
Features |
|
Applications |
|
Figure 1. Schematic diagram of TE1000 application scenarios
No. | Name | Description |
1 | Housing | Instrument enclosure |
2 | Charging Connector | Type2 vehicle connector – connects to the EV |
3 | Cooling Vent | Fan outlet for dissipating heat generated during operation |
4 | Charging Socket | Type2 vehicle socket – connects to the charger under test |
5 | Charging Socket Cover | Prevents foreign objects from entering the socket |
6 | Power Switch | Power switch with indicator light |
7 | Status Indicator Lights | Assist in determining the various operating states of the instrument |
8 | Dust and Rain Cover | Prevents foreign objects and water splashes from entering the instrument interfaces |
9 | Pulse Interface | BNC interface for pulse input and output |
10 | Type-C Port | Used for device charging and data transfer |
11 | 4G Card Slot | Reserved function |
Measurement Range | Minimum Resolution | Absolute Measurement Uncertainty (k=2) @ (15~35) °C, 1-year | Temperature Coefficient /°C @ (-25~55) °C | |
Class 0.05 | Class 0.1 | |||
±( μV/V of reading ) @(45~65)Hz | ||||
80.000 0 ~ 300.000 0 V | 0.1 mV | 250 | 500 | 10 |
Measurement Range [1] | Minimum Resolution | Absolute Measurement Uncertainty (k=2) [2] @ (15~35) °C, 1 year | Temperature Coefficient /°C @ (-25~55) °C | |
Class 0.05 | Class 0.1 | |||
±( μA/A of reading ) @(45~65)Hz | ||||
0.100 000 ~ 1.000 000 A | 1 μA | ±0.5 mA [3] | ±1 mA | — |
1.000 000 ~ 5.000 000 A | 1 μA | 500 | 1000 | — |
5.000 00 ~ 80.000 00 A | 10 μA | 250 | 500 | 10 |
Note [1]: Automatic range switching Note [2]: The parameters are derived from data after self-calibration. Self-calibration is required prior to measurement. Note [3]: Measurements below 1 A are affected by a fixed range error. | ||||
Frequency | Measurement Range | 45.000 Hz ~ 65.000 Hz |
Minimum Resolution | 0.001 Hz | |
Measurement Uncertainty (k=2) | 0.01 Hz | |
Phase | Measurement Range | 0.000°~359.999° |
Minimum Resolution | 0.001° | |
Measurement Uncertainty (k=2) | 0.025° | |
Power Factor | Measurement Range | -1.000000 ~ 0 ~ 1.000000 |
Measurement Uncertainty (k=2) | 0.1% of reading @ 0.8L~1~0.8C |
Voltage U | Current I | Absolute Measurement Uncertainty (k=2) @ (15~35) °C, 1-year | Temperature Coefficient /°C @ (-25~55) °C | |
Class 0.05 | Class 0.1 | |||
±( μW/VA of reading ) @(45~65)Hz | ||||
80 V ≤ U ≤ 300 V | 0.1 A ≤ I ≤ 1 A | 1000 ×1 A / I [5] | 2000 × 1 A / I | — |
1 A ≤ I ≤ 5 A | 1000 | 2000 | — | |
5 A < I ≤ 80 A | 500 | 1000 | 20 | |
Supports testing using both pulse method and accumulated energy method Standard energy pulse output: High-frequency full-scale corresponds to 60 kHz; low-frequency full-scale corresponds to 6 Hz Standard energy pulse input: Frequency ≤ 200 kHz, voltage: 0…3.3 V…24 V Pulse method: Automatically displays energy error with a resolution of 0.000 1% Accumulated energy display: Minimum resolution reaches 0.000 001 kWh | ||||
Note [4]: AC energy accuracy is specified only for power factors in the range of 0.8L ~ 1 ~ 0.8C. Note [5]: 1 A / I denotes the ratio of 1 ampere to the measured current. | ||||
Temperature | Measurement Range | -30 °C~60 °C |
Maximum Permissible Error | 0.5 °C |
Clock Function | Time Synchronization Method | Satellite timing |
Measurement Uncertainty (k=2) | ±1 s |
Power Supply | Primarily powered via the charging connector, supporting offline operation; can be charged via Type-C when not in use |
Power Source | Connector power supply: Uses different standard charging connectors depending on the version Wired charging: DC 5 ~ 20 V via Type-C |
Communication Interface | Wireless: Bluetooth Wired: Type-C x 1 |
Temperature Performance | Operating temperature: -25 °C — 55 °C Storage temperature: -30 °C — 70 °C Calibration temperature: (Tcal = 23 ± 2 °C) |
Humidity Performance | Operating humidity: < 100% RH Storage humidity: < 80% R H, non-condensing. |
Altitude | < 3000 m |
Dimension L×W×H (mm) | 201 mm(L) × 152 mm(D) × 145 mm(H) |
| | |
Weight | Approx. 1.8kg |
Advanced Multifunction Calibrator Advanced Electrical Reference Standards Electric Vehicle (EV)Charging Facility Tester AC/DC Standard Source /Meter Single-phase/Three-phase Standard Meter Magnetic Parameters Measurement and Calibration Magnetic Material Testing Equipment Electrical Steel Testing Equipment