1. Summary

The TD81 Series is a dedicated system for measuring the AC magnetic properties of soft magnetic materials. It consists of an AC excitation and measurement unit and fully automated measurement software. The system is capable of automatically measuring the AC magnetic characteristic parameters of soft magnetic ring specimens within the frequency range of 20 Hz to 1 MHz (refer to the ordering information), and generates corresponding magnetic characteristic curves. It features user-friendly operation, fast measurement, and excellent repeatability and reliability.


2. Features

• Electrical parameters calibration function.

• Testing mode: setting H to measure B or setting B to measure Ps.

• Testing in full frequency range with good accuracy and repeatability.

• Automatically testing with professional software.

• Automatically calculating magnetic parameters and curves.

• Complete curves drawing and data management functions.

• Modular design, easy to upgrade or maintenance.


3. Applications

TD81 AC Magnetic Properties Measuring System for Soft Magnetic Materials Applications

4. Magnetic Parameter specifications

Magnetic Parameters

Optimal Measurement Uncertainty

( k = 2 ) @1 kHz

Optimal Measurement Repeatability

Main magnetic parameters

Ps

2.0%

1.0%

μa

3.0%

1.0%

Bm

1.0%

0.5%

Hm

1.0%

0.5%

δ

5.0%

1.5%

Other parameters

Br

2.0%

1.0%

Hc

3.0%

1.0%

μ’

3.0%

1.0%

μ′′

3.0%

1.0%

μL

3.0%

1.0%

• Testing conditions:( 23±5 )°C,20 Hz ≤ F ≤ 20 kHz,demagnetized before testing.

• The ratio of the outer diameter to the inner diameter of the measured specimen should not be greater than 1.4, preferably less than 1.25.


5. Electrical Parameter Specifications

5.1 TD8110 / TD8120 / TD8130

Excitation Voltage Range

10 mVpk~200 Vpk

Excitation Current Range

0.5 mApk~20 Apk

Frequency Range

20 Hz... 100 kHz... 200 kHz...500 kHz Optional

Optimal Frequency Measurement Uncertainty

0.1%

Frequency Range (Hz)

Maximum output power (peak value)

Optimal Measurement Uncertainty of Voltage and Current (k=2) Optimal Measurement Accuracy of Active Power (k=2)

20 ≤ F ≤ 1 k

700 VA

0.05%*RG ①

0.1%*FS ②

1 k < F ≤ 10 k

700 VA

0.1%*RG ①

0.2%*FS ②

10 k < F ≤ 100 k

700 VA

1.0 %*RG ①

2.0%*FS ②

100 k < F ≤ 300 k

200 VA

2.5%*RG ①

5.0%*FS ②

300 k < F ≤ 500 k

100 VA

5.0%*RG ①

8.0%*FS ②

Notes ①:RG is range value;②:FS = Voltage range value × Current range value


5.2 TD8140

Excitation Voltage Range

10 mVpk~68Vpk

Excitation Current Range

0.5 mApk~6 Apk

Frequency Range

20 Hz... 1 MHz

Optimal Frequency Measurement Uncertainty

0.1%

Frequency Range (Hz)

Maximum output power (peak value) Optimal Measurement Uncertainty of Voltage and Current (k=2) Optimal Measurement Accuracy of Active Power (k=2)

20 ≤ F ≤ 1 k

400VA

0.05%*RG ①

0.1%*FS ②

1 k < F ≤ 10 k

400VA

0.1%*RG ①

0.2%*FS ②

10 k < F ≤ 100 k

400VA

1.0 %*RG ①

2.0%*FS ②

100 k < F ≤ 300 k

240 VA

2.5%*RG ①

5.0%*FS ②

300 k < F ≤ 500 k

240 VA

5.0%*RG ①

8.0%*FS ②

500 k < F ≤ 1 M

200 VA

8.0%*RG ①

12%*FS ②

Notes ①:RG is range value;②:FS = Voltage range value × Current range value


6. General specifications

Power Supply

AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz

Temperature Performance

Operating Temperature:0°C~45°C

Storage Temperature:-20°C~70°C

Humidity Performance

Operating Storage:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C

Storage Humidity:(20%~80%) R·H,non-condensing


7. Ordering Information


8. Auto-Testing Software

  • The software runs on the Windows operating system, offering intuitive and user-friendly operation.

  • Fully automated control and computation with intelligent judgment greatly minimize errors caused by manual operations.

  • Real-time display of current, voltage, and power values; supports simultaneous display of I(t), U(t), B(t) waveforms and B(H) hysteresis loops in multiple windows. Real-time monitoring of waveforms and instrument status with the ability to stop the process at any time.

  • Supports pre-setting multiple loss or magnetic induction test schemes by frequency, with save and load functions.

  • Test reports include complete curve graphs, test results, test conditions, and specimen parameters.

  • After multi-point testing, it can display B(H) hysteresis loop clusters, B(H) magnetization curves, μa(H) permeability curves, and Ps(B) loss curves, with coordinate details available for each data point.

  • Powerful file management functions, including auto-save, delete, and clear all data.

  • Multiple export formats for test results: direct printing; export as JPG image or Excel spreadsheet.

  • Compatible with various printer models and supports print preview. User name and logo can be conveniently added to the report.


Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information
Leave a Message
SEND A MESSAGE

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap