TY1000
TUNKIA
| Availability: | |
|---|---|

*Above picture is only for reference, subject to actual delivery
1. Summary
TY1000 is an intelligent system specifically designed for measuring the magnetic properties of permanent magnet materials. It consists of an excitation and measurement host, electromagnet, magnetic measurement sensors, computer, and measurement software. It is suitable for measuring the magnetic properties of various types of permanent magnet materials and plotting the corresponding magnetic characteristic curves. The system features easy operation, fast measurement, good repeatability, and high reliability.
2. Features
Built-in electrical parameter calibration.
Demagnetization via slow amplitude reduction.
Wide-range, stable, continuously adjustable current.
Minimal integrator drift and Hall probe nonlinearity.
Bipolar variable magnetization power supply for easy magnetization/demagnetization.
B or J measured via coil + fluxmeter; J-coil supports automatic residual area compensation.
H measured via magnetometer + Hall probe or H-coil + fluxmeter.
Various coils and probes available; customizable for sample size.
150 mm electromagnet (optional pole reducers): up to 2.55 T.
130 mm electromagnet (optional pole reducers): up to 2.45 T.
Professional software automates measurement and curve plotting; supports data management.
Modular design for host and magnetometers enables easy upgrades and maintenance.
Optional high-temperature testing for evaluating thermal effects on magnetic properties.
3. Application


*Above picture is only for reference, subject to actual delivery
1. Summary
TY1000 is an intelligent system specifically designed for measuring the magnetic properties of permanent magnet materials. It consists of an excitation and measurement host, electromagnet, magnetic measurement sensors, computer, and measurement software. It is suitable for measuring the magnetic properties of various types of permanent magnet materials and plotting the corresponding magnetic characteristic curves. The system features easy operation, fast measurement, good repeatability, and high reliability.
2. Features
Built-in electrical parameter calibration.
Demagnetization via slow amplitude reduction.
Wide-range, stable, continuously adjustable current.
Minimal integrator drift and Hall probe nonlinearity.
Bipolar variable magnetization power supply for easy magnetization/demagnetization.
B or J measured via coil + fluxmeter; J-coil supports automatic residual area compensation.
H measured via magnetometer + Hall probe or H-coil + fluxmeter.
Various coils and probes available; customizable for sample size.
150 mm electromagnet (optional pole reducers): up to 2.55 T.
130 mm electromagnet (optional pole reducers): up to 2.45 T.
Professional software automates measurement and curve plotting; supports data management.
Modular design for host and magnetometers enables easy upgrades and maintenance.
Optional high-temperature testing for evaluating thermal effects on magnetic properties.
3. Application

4. Excitation and Measurement
Magnetizing Current | Output Range | 0~± 25 A |
Max. Power | 1500 VA (peak) | |
Protection Function | Over voltage, over current, overload, overheating | |
Tesla Meter | Range | 0~4000 mT |
Optimal Measurement Uncertainty(k=2) | 0.5%*RG within 2500 mT [1] | |
Characteristic | Hall-probe nonlinear correction function | |
Flux Meter | B Flux Meter Range | 0~20 mWb, for magnetic flux measurement |
H Flux Meter Range | 0~40 mWb, for magnetic field strength measurement | |
Min. Resolution | 0.1 μWb | |
Zero-Drift | Drift better than ±1 μWb/min, with auto-zero function | |
Note:[1] RG is the range values. | ||
5. Reproducibility
Magnetic Parameters | Typical Values | Guaranteed Value (Al Ni Co) | Guaranteed Value (Ferrite, Fe-Cr-Co, Rare Earth Magnet ) |
Br | 0.3% | 1.0% | 2.0% |
Hcb | 0.3% | 1.0% | 2.0% |
Hcj | 0.3% | 1.0% | 2.0% |
(BH)max | 0.3% | 1.5% | 3.0% |
Test temperature: 23 °C ± 5 °C.
Specimen dimensions must strictly comply with GB/T 3217-2013 requirements.
Guaranteed values meet the requirements of relevant IEC standards.
6. General Specifications
Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Temperature Performance | Working Temperature:0°C~40°C; Storage Temperature:-20°C~70°C |
Humidity Performance | Working Humidity:40%~80% R·H,No condensation Store Humidity:< 95% R·H,No condensation |
7. Electromagnet (optional)

7.1 Features
The electromagnet supports interchangeable pole pieces of various specifications and is excited via a DC current source.
Generates a strong, continuously adjustable magnetic field with good uniformity and linearity.
Can be used to magnetize permanent magnet samples for magnetic property testing.
Low input power and magnetic field consumption, environmentally friendly and energy-efficient.
Naturally cooled, with no need for external water chillers.
Model | Type | Air gap | Imax | Hmax (10 mm Gap) |
TY1500-130 | Vertical 130 Type | 0~60 mm single side adjustable | DC ,± 25 A | 2.45 T |
TY1500-150 | Vertical 150 Type | 0~80 mm single side adjustable | DC, ± 25 A | 2.55 T |
Poles Type | Model | Pole Diameter | Pole Face Diameter | Hmax (10 mm Gap) |
Room temperature | TY1550-130-130 | 130 mm | 130 mm | 1.5 T |
TY1550-130-60 | 130 mm | 60 mm | 2.45 T | |
TY1550-150-150 | 150 mm | 150 mm | 1.5 T | |
TY1550-150-80 | 150 mm | 80 mm | 2.55 T | |
High temperature | TY1550-T-130-80 | 130 mm | 80 mm | 1.8 T |
TY1550-T-150-80 | 150 mm | 80 mm | 2.0 T |
Note: The above accessories are optional according to the testing requirements.
8. Auto-testing Software
Software runs on Windows, offering intuitive and user-friendly operation.
Magnetization, demagnetization, and testing of typical permanent magnets are completed in one automated cycle with short measurement time.
Fully automated control and intelligent judgment minimize manual error.
Automatically calculates data, applies temperature coefficient correction, and calibrates range coefficients.
Main interface displays the magnetization curve in real time, with the option to stop measurement at any time.
Excitation current output percentage is freely adjustable; fluxmeter and teslameter zero-drift can be corrected.
Measurement data is automatically saved. Reports include complete curves, results, test conditions, and sample parameters.
9. Configuration List
No. | Item Name | Number | Configuration | Note |
1 | TY1000 | 1 | Standard | / |
2 | Hall probe and bracket | 1 | Standard | / |
3 | J coils or J-H coils | 1 | Standard | According to specimen size |
4 | Testing software | 1 | Standard | Installation CD-ROM |
5 | Test wire and junction box | 1 | Standard | / |
6 | TY1500 electromagnet | 1 | Optional | See electromagnet model |
7 | TY1550 electromagnet poles | 1 | Optional | See electromagnet poles model |
8 | TY1900 Specimen Heating Device | 1 | Optional | Used for high temperature performance testing |
9 | High temperature J-H coils | 1 | Optional | |
10 | Reference specimen | 1 | Optional | Including certificate |
11 | Segment poles | 1 | Optional | According to specimen size |
12 | Workbench | 1 | Optional | Third party Products |
13 | Computer | 1 | Optional | Third party Products |
14 | Printer | 1 | Optional | Third party Products |
• Note: The above is only for reference. The specific configuration list depends on the technical protocol.
4. Excitation and Measurement
Magnetizing Current | Output Range | 0~± 25 A |
Max. Power | 1500 VA (peak) | |
Protection Function | Over voltage, over current, overload, overheating | |
Tesla Meter | Range | 0~4000 mT |
Optimal Measurement Uncertainty(k=2) | 0.5%*RG within 2500 mT [1] | |
Characteristic | Hall-probe nonlinear correction function | |
Flux Meter | B Flux Meter Range | 0~20 mWb, for magnetic flux measurement |
H Flux Meter Range | 0~40 mWb, for magnetic field strength measurement | |
Min. Resolution | 0.1 μWb | |
Zero-Drift | Drift better than ±1 μWb/min, with auto-zero function | |
Note:[1] RG is the range values. | ||
5. Reproducibility
Magnetic Parameters | Typical Values | Guaranteed Value (Al Ni Co) | Guaranteed Value (Ferrite, Fe-Cr-Co, Rare Earth Magnet ) |
Br | 0.3% | 1.0% | 2.0% |
Hcb | 0.3% | 1.0% | 2.0% |
Hcj | 0.3% | 1.0% | 2.0% |
(BH)max | 0.3% | 1.5% | 3.0% |
Test temperature: 23 °C ± 5 °C.
Specimen dimensions must strictly comply with GB/T 3217-2013 requirements.
Guaranteed values meet the requirements of relevant IEC standards.
6. General Specifications
Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
Temperature Performance | Working Temperature:0°C~40°C; Storage Temperature:-20°C~70°C |
Humidity Performance | Working Humidity:40%~80% R·H,No condensation Store Humidity:< 95% R·H,No condensation |
7. Electromagnet (optional)

7.1 Features
The electromagnet supports interchangeable pole pieces of various specifications and is excited via a DC current source.
Generates a strong, continuously adjustable magnetic field with good uniformity and linearity.
Can be used to magnetize permanent magnet samples for magnetic property testing.
Low input power and magnetic field consumption, environmentally friendly and energy-efficient.
Naturally cooled, with no need for external water chillers.
Model | Type | Air gap | Imax | Hmax (10 mm Gap) |
TY1500-130 | Vertical 130 Type | 0~60 mm single side adjustable | DC ,± 25 A | 2.45 T |
TY1500-150 | Vertical 150 Type | 0~80 mm single side adjustable | DC, ± 25 A | 2.55 T |
Poles Type | Model | Pole Diameter | Pole Face Diameter | Hmax (10 mm Gap) |
Room temperature | TY1550-130-130 | 130 mm | 130 mm | 1.5 T |
TY1550-130-60 | 130 mm | 60 mm | 2.45 T | |
TY1550-150-150 | 150 mm | 150 mm | 1.5 T | |
TY1550-150-80 | 150 mm | 80 mm | 2.55 T | |
High temperature | TY1550-T-130-80 | 130 mm | 80 mm | 1.8 T |
TY1550-T-150-80 | 150 mm | 80 mm | 2.0 T |
Note: The above accessories are optional according to the testing requirements.
8. Auto-testing Software
Software runs on Windows, offering intuitive and user-friendly operation.
Magnetization, demagnetization, and testing of typical permanent magnets are completed in one automated cycle with short measurement time.
Fully automated control and intelligent judgment minimize manual error.
Automatically calculates data, applies temperature coefficient correction, and calibrates range coefficients.
Main interface displays the magnetization curve in real time, with the option to stop measurement at any time.
Excitation current output percentage is freely adjustable; fluxmeter and teslameter zero-drift can be corrected.
Measurement data is automatically saved. Reports include complete curves, results, test conditions, and sample parameters.
9. Configuration List
No. | Item Name | Number | Configuration | Note |
1 | TY1000 | 1 | Standard | / |
2 | Hall probe and bracket | 1 | Standard | / |
3 | J coils or J-H coils | 1 | Standard | According to specimen size |
4 | Testing software | 1 | Standard | Installation CD-ROM |
5 | Test wire and junction box | 1 | Standard | / |
6 | TY1500 electromagnet | 1 | Optional | See electromagnet model |
7 | TY1550 electromagnet poles | 1 | Optional | See electromagnet poles model |
8 | TY1900 Specimen Heating Device | 1 | Optional | Used for high temperature performance testing |
9 | High temperature J-H coils | 1 | Optional | |
10 | Reference specimen | 1 | Optional | Including certificate |
11 | Segment poles | 1 | Optional | According to specimen size |
12 | Workbench | 1 | Optional | Third party Products |
13 | Computer | 1 | Optional | Third party Products |
14 | Printer | 1 | Optional | Third party Products |
• Note: The above is only for reference. The specific configuration list depends on the technical protocol.