TD3760 Complex Waveform Testing Device

TD3760 is an AC power device specially designed for complex waveform current influence test of new AC energy meters. It meets the test requirements of relevant current influence in OIML R46. The device directly outputs complex current waveforms with high stability and accuracy through the three phase precision standard power source, which can complete the following test items.
(1)Impact Test of DC and Even Harmonics (The device can directly output half-wave current, no longer use the traditional scheme (rectifier diode) )
(2)Impact Test of Harmonic in Voltage-current Circuits,
(3)Impact Test of Inter-harmonic in Current Circuits
(4)Impact Test of Odd Harmonic in Current Circuits
(5)High-order Harmonic Test
(6)Burden Current Fast Change Test
Up to 12 test positions. Accuracy Class 0.05.
  • TD3760

  • TUNKIA

Availability:


TD3760 Complex Waveform Testing Device


TD3760 Complex Waveform Current Influence of Energy Meter Testing Apparatus


1. Summary

TD3760 is an AC power device specially designed for complex waveform current influence test of new AC energy meters. It meets the test requirements of relevant current influence in OIML R46. The device directly outputs complex current waveforms with high stability and accuracy through the three phase precision standard power source, which can complete the following test items.

(1)Impact Test of DC and Even Harmonics (The device can directly output half-wave current, no longer use the traditional scheme (rectifier diode) )

(2)Impact Test of Harmonic in Voltage-current Circuits,

(3)Impact Test of Inter-harmonic in Current Circuits

(4)Impact Test of Odd Harmonic in Current Circuits

(5)High-order Harmonic Test

(6)Burden Current Fast Change Test

Up to 12 test positions. Accuracy Class 0.05.


2. Features

  • Current Output: Provides a full-wave RMS AC current output ranging from 20 mA to 120 A, and a half-wave peak current output from 20√2 mApk to 120√2 Apk. It fully meets the requirements for influence quantity testing with complex current waveforms, including those with a maximum current (Imax) of up to 100 A for smart meters, while ensuring stable output values even under full-load conditions.

  • Direct Half-Wave Output: For DC even-order harmonic tests, the device can directly output a maximum peak half-wave current of 120√2 Apk through the power amplifier, eliminating the need for traditional rectifier diode solutions. This design avoids the need for a separate half-wave rectification circuit and resolves impedance matching issues commonly associated with diode rectifiers.

  • Harmonic Output Capability: Supports harmonic output from the 2nd to the 63rd order @ 50 Hz / 60 Hz, with programmable control of harmonic amplitude and phase. This forms the basis for conducting complex waveform tests and high-order harmonic sweep tests on the meter under test.

  • Impact Test of Harmonic in Voltage-current Circuits: Built in square-wave, peaked wave, inter-harmonic and other schemes.

  • Impact Test of Inter-harmonic in Current Circuits: The device can directly output the inter-harmonic.

  • Impact Test of Odd Harmonic in Current Circuits: The device can directly output the odd harmonic.

  • High-order Harmonic Test: Built in high-order harmonic test schemes. So it automatically superposes the 15fnom to 40fnom sweep signals to the voltage and current loops and reads the data of each harmonic to measure the error offset caused by the high-order harmonic.

  • Burden Current Fast Change Test: The user can set the duration of ton and toff, as well as the total time for a single test. The current switches at zero crossing and switches off and on within one nominal frequency period. The repetition time of single test was more than 4 hours.

  • Communication: Communicate with DUT through RS-485 communication port.

  • Multi-position Verification Platform: Optional 3,6,12,16 positions.

  • Dedicated Calibration Software: Supports semi-automatic or fully automatic calibration of the meter under test, as well as data management and certificate export. The software features multi-measurement capability at a single test point with configurable time intervals and automatically generates error curve charts.


3. Typical Output Waveform

3.1 Half-wave Rectification Waveform (DC and Even Harmonics)

TD3760 Complex Waveform Testing Apparatus Half-wave Rectification Waveform (DC and Even Harmonics) TEST


3.2 Waveform of the Impact Test of Harmonic

TD3760 Complex Waveform Testing Apparatus Waveform of the Impact Test of Harmonic TEST1

TD3760 Complex Waveform Testing Apparatus Waveform of the Impact Test of Harmonic TEST 2


3.3 Inter-harmonic

TD3760 Complex Waveform Testing Apparatus Inter-harmonic TEST

3.4 Odd Harmonic


TD3760 Complex Waveform Testing Apparatus Odd Harmonic TEST

4. Specifications

4.1 AC Voltage Output

Range

Resolution

Short-term Stability ( % / min )

Accuracy

± (ppm of reading + ppm of range) [1]

Distortion Factor ( % )

60 V

0.1 mV

0.01

120 + 80

< 0.3

120 V

1 mV

0.01

120 + 80

< 0.3

240 V

1 mV

0.01

120 + 80

< 0.3

480 V

1 mV

0.01

120 + 80

< 0.3

Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).

• Output range: 6 V~528 V, 6-digits display, load capacity: 15 VA/ (phase ·position)

• Symmetry: Voltage ≤ 0.2%, Phase ≤ 0.5°

• Protective function: Short-circuit protection, Overload protection


4.2 AC Current Output

Range

Resolution

Short-term Stability ( % / min )

Accuracy

± (ppm of reading + ppm of range)

Distortion Factor ( % )

100 mA

1 μA

0.01

200 + 100

< 0.2

200 mA

1 μA

0.01

200 + 100

< 0.2

500 mA

1 μA

0.01

200 + 100

< 0.2

1 A

10 μA

0.01

200 + 100

< 0.2

2 A

10 μA

0.01

200 + 100

< 0.2

5 A

10 μA

0.01

200 + 100

< 0.2

10 A

100 μA

0.01

200 + 100

< 0.2

20 A

100 μA

0.01

200 + 100

< 0.2

50 A

100 μA

0.01

200 + 100

< 0.2

100 A

1 mA

0.01

200 + 100

< 0.2

• Output range: 20mA~120 A@ full wave, 6-digits display

• Symmetry: Current ≤ 0.5%, Phase ≤ 0.5°

• Protective function: Open-circuit protection, Overload protection, Overheating protection


4.3 Frequency / Phase / Harmonic

Type

Range of Regulation

Accuracy

Frequency

45.000 0Hz~100.000 Hz

50 ppm*RD

Phase

0.000°~359.999°

0.012°

Harmonic Output

the 2nd ~ 63st @ 50 Hz / 60 Hz (support single or multiple simultaneous stacking), harmonic content and phase are programmable (Amplitude: 0~40% , Phase: 0.0°~359.9°).


4.4 Power / Electrical Energy

• Uncertainty of Measurement (k=2): 0.05%*RD

• Output Power Stability: 0.02% / 2min

• Power/Electric Energy Measuring Range: The combination of AC voltage and current range

• Power Factor Measuring Range: -1.000 00…0.000 00…1.000 00

• Standard Electric Energy Pulse output: High frequency pulse output port outputs 60 kHz at full range, low frequency pulse output port outputs 6 Hz at full range;

• Standard Energy Pulse Input: Frequency ≤ 200 kHz, Voltage: 0...3.3 V...24 V

• Electric Energy Error Display: Auto, resolution is 0.0001%.


5. General Specifications

Power Supply

Single-phase AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz

Warm Up Time

30 min

Temperature

Operating Temperature: 18°C~28°C;

Storage Temperature: -10°C~55°C

Humidity Performance

Operating Humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C

Storage Humidity: (20%~80%) R·H, Non-Condensing

Communication Interface

RS232, RS485, LAN


6. Ordering Information

TD3760 Complex Waveform Testing Apparatus Ordering Information



Previous: 
Next: 

SIGN UP FOR NEWSLETTER

Get latest deals, newsletter and technical information
Leave a Message
SEND A MESSAGE

INFORMATION

CONTACT US

 WhatsApp:+86-18773180215
     Wechat: 18773180215
 Phone: +86-18773180215
 E-mail: global@tunkia.com
E-mail: Eugene@tunkia.com
 Address: NO.16 Panpan Road, Changsha
Copyright  2021 TUNKIA Co., Ltd. All Rights Reserved. Supported by leadong.comSitemap